The effect of the field on the IRt/c: since the measuring signal is electrically isolated from the housing, the IRt/c will operate in even a very strong field. The shield wire should be attached to a proper signal ground. If there is excessive heating from the field, consider using the cooling jacket kit, with the same water source as is used to cool the coil. |
 |
The field-of-view: the preferred method is to view the part between the coil turns or from the end. Select the IRt/c model that best suits the requirements. For small gaps between coils, consider the focused models |
 |
Part temperature: IRt/c models can be used to measure target temperatures up to 5000°F (2760°C). Select the correct model for the control temperature desired. |
 |
Part surface material: For bare metal parts the Lo E models are recommended. For coated or non-metal surfaces the Hi E models should be used. |